Difference between revisions of "SwissCovid Exposure Score Calculation (Q4799)"
Jump to navigation
Jump to search
(Changed [en] description: dp-3t report first published in June 26th 2020, second version in July 6th, third version in September 11th) |
(Created claim: see also (P12): SwissCovid élargit son filet (Q4874)) |
||
Property / see also | |||
+ | |||
Property / see also: SwissCovid élargit son filet / rank | |||
+ | Normal rank |
Latest revision as of 16:41, 15 September 2020
dp-3t report first published in June 26th 2020, second version in July 6th, third version in September 11th
Language | Label | Description | Also known as |
---|---|---|---|
English |
SwissCovid Exposure Score Calculation
|
dp-3t report first published in June 26th 2020, second version in July 6th, third version in September 11th
|
Statements
June 26th version . new version on July 6th. new version on Sept 11th
0 references
11 September 2020
0 references
version 1 : t1=50dB and t2=55dB. The selected first threshold of 50dB results in a 67% precision within 1.5m with a 36% recall, and a precision of 85% within 2m. The selected second threshold of 55dB - associated with half-weight - has a precision of 90% within 3m.
0 references
version 2; | t1=53dB, t2=60dB The thresholds were updated on July 06 to increase the recall. The selected first threshold of 53dB results in a 60% precision within 1.5m with a 50% recall, and a precision of 78% within 2m. The selected second threshold of 60dB - associated with half-weight - has a precision of 85% within 3m.
0 references
version 3; | t1=55dB, t2=63dB The thresholds were updated on Sept 11th to increase the recall. The selected first threshold of 55dB results in a 57.3% precision within 1.5m with a 50% recall, and a precision of 76.9% within 2m. The selected second threshold of 60dB - associated with half-weight - has a precision of 87 %within 3m.
0 references