dp-3t report
+
dp-3t report first published in June 26th 2020, second version in July 6th, third version in September 11th
Property / official website: https://github.com/admin-ch/PT-System-Documents/blob/master/SwissCovid-ExposureScore.pdf / qualifier
 +
comment: June 26th version . new version on July 6th. new version on Sept 11th
Property / dateProperty / date
-
26 June 2020
Timestamp+2020-06-26T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0
+
11 September 2020
Timestamp+2020-09-11T00:00:00Z
Timezone+00:00
CalendarGregorian
Precision1 day
Before0
After0
Property / concerns
 +
Property / concerns: Google/Apple contact tracing protocol / rank
 +
Normal rank
Property / see also
 +
Property / see also: SwissCovid élargit son filet / rank
 +
Normal rank
Property / instance of
 +
Property / instance of: report / rank
 +
Normal rank
Property / comment
 +
version 1 : t1=50dB and t2=55dB. The selected first threshold of 50dB results in a 67% precision within 1.5m with a 36% recall, and a precision of 85% within 2m. The selected second threshold of 55dB - associated with half-weight - has a precision of 90% within 3m.
Property / comment: version 1 : t1=50dB and t2=55dB. The selected first threshold of 50dB results in a 67% precision within 1.5m with a 36% recall, and a precision of 85% within 2m. The selected second threshold of 55dB - associated with half-weight - has a precision of 90% within 3m. / rank
 +
Normal rank
Property / comment
 +
version 2; | t1=53dB, t2=60dB The thresholds were updated on July 06 to increase the recall. The selected first threshold of 53dB results in a 60% precision within 1.5m with a 50% recall, and a precision of 78% within 2m. The selected second threshold of 60dB - associated with half-weight - has a precision of 85% within 3m.
Property / comment: version 2; | t1=53dB, t2=60dB The thresholds were updated on July 06 to increase the recall. The selected first threshold of 53dB results in a 60% precision within 1.5m with a 50% recall, and a precision of 78% within 2m. The selected second threshold of 60dB - associated with half-weight - has a precision of 85% within 3m. / rank
 +
Normal rank
Property / comment
 +
version 3; | t1=55dB, t2=63dB The thresholds were updated on Sept 11th to increase the recall. The selected first threshold of 55dB results in a 57.3% precision within 1.5m with a 50% recall, and a precision of 76.9% within 2m. The selected second threshold of 60dB - associated with half-weight - has a precision of 87 %within 3m.
Property / comment: version 3; | t1=55dB, t2=63dB The thresholds were updated on Sept 11th to increase the recall. The selected first threshold of 55dB results in a 57.3% precision within 1.5m with a 50% recall, and a precision of 76.9% within 2m. The selected second threshold of 60dB - associated with half-weight - has a precision of 87 %within 3m. / rank
 +
Normal rank

Latest revision as of 16:41, 15 September 2020

dp-3t report first published in June 26th 2020, second version in July 6th, third version in September 11th
Language Label Description Also known as
English
SwissCovid Exposure Score Calculation
dp-3t report first published in June 26th 2020, second version in July 6th, third version in September 11th

    Statements

    June 26th version . new version on July 6th. new version on Sept 11th
    0 references
    11 September 2020
    0 references
    0 references
    version 1 : t1=50dB and t2=55dB. The selected first threshold of 50dB results in a 67% precision within 1.5m with a 36% recall, and a precision of 85% within 2m. The selected second threshold of 55dB - associated with half-weight - has a precision of 90% within 3m.
    0 references
    version 2; | t1=53dB, t2=60dB The thresholds were updated on July 06 to increase the recall. The selected first threshold of 53dB results in a 60% precision within 1.5m with a 50% recall, and a precision of 78% within 2m. The selected second threshold of 60dB - associated with half-weight - has a precision of 85% within 3m.
    0 references
    version 3; | t1=55dB, t2=63dB The thresholds were updated on Sept 11th to increase the recall. The selected first threshold of 55dB results in a 57.3% precision within 1.5m with a 50% recall, and a precision of 76.9% within 2m. The selected second threshold of 60dB - associated with half-weight - has a precision of 87 %within 3m.
    0 references